1. Respiratory Risk
Respiratory Protective Equipment Overview
Respiratory Protective Equipment, often shortened to RPE, protects the wearer from inhaling hazardous substances. These may include dusts, fumes, fibres, gases, vapours, biological agents and oxygen-deficient atmospheres where specialist breathing apparatus is required.
Occupational lung disease is a serious workplace risk. Conditions linked to workplace inhalation exposure can include silicosis, occupational asthma, COPD and other irreversible illnesses. RPE is the last line of defence and should be used alongside higher-level controls such as substitution, enclosure, extraction, ventilation and safe working methods.
Key point: RPE must be matched to the specific substance, concentration, exposure limit, wearer and work environment. Selecting a mask without a COSHH assessment can leave workers under-protected.
Common Airborne Hazards
- Dusts: wood dust, construction dust, flour dust, cement dust and general workplace particulates.
- Respirable crystalline silica: created by cutting, grinding, drilling or crushing silica-containing materials.
- Fumes: welding fume, metal fume, soldering fume and thermal decomposition products.
- Fibres: asbestos fibres and man-made mineral fibres where exposure may occur.
- Gases and vapours: solvents, adhesives, paint vapours, acid gases, ammonia and other chemical atmospheres.
- Biological agents: airborne pathogens and bioaerosols in healthcare, laboratory or waste environments.
- Oxygen-deficient atmospheres: confined spaces or unknown atmospheres where filtering RPE is not suitable.
Important: surgical or medical face masks are not RPE for occupational airborne hazards. Only suitable UKCA or CE-marked RPE to the correct EN standard should be used for workplace respiratory protection.
What Is APF?
APF means Assigned Protection Factor. It describes the level of protection a correctly selected, fitted, maintained and used item of RPE should provide. For example, APF 20 means the device reduces the inhaled concentration to one twentieth of the workplace concentration when used correctly.
A simple way to think about APF is: required APF equals workplace concentration divided by the workplace exposure limit. This is why exposure level and substance information are essential before RPE is selected.
2. Legal Requirements
Legal and Regulatory Requirements
RPE should be selected through COSHH assessment where workers may be exposed to hazardous substances by inhalation. Employers should first prevent or control exposure by other means, then use RPE as an additional control where risks remain.
Where RPE is required, it should be adequate, suitable, correctly fitted, compatible with other PPE, maintained, cleaned, stored and used by trained workers. Tight-fitting RPE requires fit testing for each wearer.
Useful HSE Guidance
3. RPE Types
Types and Classifications of RPE
RPE is split broadly into filtering devices and breathing apparatus. Filtering devices clean the surrounding air and require adequate oxygen. Breathing apparatus supplies clean air and is used where the atmosphere is oxygen-deficient, unknown or immediately dangerous to life or health.
Critical rule: filtering RPE does not create oxygen. It must not be used in oxygen-deficient confined spaces or unknown atmospheres.
Filtering Devices
Filtering devices are used only where the surrounding air contains enough oxygen and the contaminant can be filtered by the selected device and filter type.
| Type |
Standard |
APF |
Suitable For |
| FFP1 Disposable |
EN 149 |
4× WEL |
Low-hazard nuisance dust only. Not suitable for silica, asbestos or welding fume. |
| FFP2 Disposable |
EN 149 |
10× WEL |
Moderate dust hazards and some biological hazards. |
| FFP3 Disposable |
EN 149 |
20× WEL |
High-hazard dusts, silica, some asbestos survey work, welding fume and biohazards. |
| Half Mask + P2 Filter |
EN 140 + EN 143 |
10× WEL |
Reusable dust protection and an alternative to FFP2. |
| Half Mask + P3 Filter |
EN 140 + EN 143 |
20× WEL |
Reusable protection for high-hazard dusts and an alternative to FFP3. |
| Half Mask + Gas Filter |
EN 140 + EN 14387 |
10× WEL |
Gases and vapours where the correct filter type is selected. |
| Full Face Mask + P3 Filter |
EN 136 + EN 143 |
20× WEL |
High-hazard dust plus eye and face protection. |
| PAPR TH2 Loose Hood |
EN 12941 |
20× WEL |
Bearded workers and tasks where tight-fitting RPE cannot be used. |
| PAPR TH3 Loose Hood |
EN 12941 |
500× WEL |
Higher-risk tasks such as asbestos removal, lead work, radionuclides and regular welding where suitable. |
Breathing Apparatus
Breathing apparatus supplies clean air rather than filtering the surrounding atmosphere. It is used where oxygen may be deficient, where the atmosphere is unknown or where filtering RPE is not suitable.
| Type |
Standard |
APF |
Use |
| Airline / Supplied Air |
EN 14593 |
1000×+ |
Paint spraying, confined space entry and supplied air tasks. |
| SCBA Open Circuit |
EN 137 |
2000×+ |
Fire, rescue, unknown atmospheres and oxygen-deficient conditions. |
4. Filters
Particle, Gas and Vapour Filters
The filter must match the substance. A dust filter will not protect against gas or vapour. An organic vapour filter will not protect against fine particles unless a suitable particle filter is also fitted. Combination filters may be needed where more than one hazard is present.
| Filter Type |
Used For |
Important Notes |
| P1 / P2 / P3 |
Particles, dusts and fumes. |
P3 offers the highest particle protection in this group. |
| A Filter |
Organic vapours such as many solvents and adhesives. |
Must be matched to the specific chemical and breakthrough time. |
| B Filter |
Inorganic gases and vapours. |
Check substance compatibility before use. |
| E Filter |
Acid gases. |
Use only where selected through assessment. |
| K Filter |
Ammonia and organic ammonia derivatives. |
Replace in line with manufacturer guidance or if breakthrough is suspected. |
| ABEK Combination |
Mixed gas and vapour hazards. |
Often combined with particle protection where dusts or fumes are also present. |
Gas filter warning: gas filters saturate invisibly. Replace them at the manufacturer’s stated service time, when the filter expiry is reached, or immediately if odour, taste or irritation is detected.
5. Applications
Industry Applications
Different work tasks create very different inhalation hazards. Selection should be based on the specific airborne substance, concentration, exposure duration, working method and whether other controls such as LEV are in place.
| Industry / Task |
Airborne Hazard |
Typical RPE |
| Concrete Cutting / Grinding |
Respirable crystalline silica. |
FFP3 minimum; PAPR TH3 for prolonged or high-exposure work where suitable. |
| Welding |
Welding fume. |
FFP3 for short-duration work with LEV; PAPR TH3 for regular welding where suitable. |
| Asbestos Licensed Removal |
Asbestos fibres at high concentration. |
TH3 PAPR or full-face P3 as part of licensed contractor controls. |
| Wood Dust |
Hardwood dust and other wood dust exposure. |
Half-face mask with P3 filter where required by assessment. |
| Spray Painting |
Isocyanates and paint mist. |
Airline or suitable powered system selected through assessment. |
| Chemical Handling |
Organic vapours, solvents and adhesives. |
Half-face mask with A filter or ABEK combination where suitable. |
| Confined Space |
Oxygen deficiency or unknown atmosphere. |
SCBA or airline. Filtering RPE is not suitable. |
| Healthcare |
Airborne biological agents. |
FFP3 for aerosol-generating procedures where required. |
| Lead Work |
Lead fume or dust. |
FFP3 minimum; TH3 PAPR for higher-exposure tasks where suitable. |
Jaybee Supplies Can Help Source Respiratory PPE
From FFP2 and FFP3 disposable masks to reusable half masks, full-face respirators, P3 filters, gas filters, powered respirators and wider PPE, Jaybee Supplies can help your team choose suitable respiratory protection.
Shop PPE Equipment
6. Selection
How to Select the Right RPE
RPE selection must be based on a COSHH assessment. Without knowing the substance, concentration, workplace exposure limit and task conditions, it is not possible to choose the correct level of protection.
Selection principle: identify the airborne hazard first, calculate the required APF, confirm the filter or air supply method, check wearer suitability, complete fit testing where required and train workers before use.
Step 1: Complete a COSHH Assessment
A COSHH assessment should identify the hazardous substance, how exposure occurs, the likely concentration, the workplace exposure limit, the duration of exposure and existing controls such as LEV or enclosure.
Step 2: Choose the Required APF
- Low-level nuisance dust: lower APF devices may be suitable only where risk is low and assessment confirms suitability.
- Silica, welding fume or high-hazard dust: FFP3 or reusable P3 protection is commonly required as a minimum.
- High exposure or regular work: powered respirators or higher APF systems may be needed.
- Unknown or oxygen-deficient atmospheres: filtering RPE should not be used; supplied air or SCBA may be required.
Step 3: Fit Test Tight-Fitting RPE
All tight-fitting RPE, including FFP2, FFP3, half masks and full-face masks, must be fit tested for each individual wearer. A leaking face seal can defeat the protection rating.
- Qualitative fit test: a pass or fail test using a test agent, commonly used for disposable and half-mask RPE.
- Quantitative fit test: a numerical fit factor test, required for full-face masks.
- Bearded workers: tight-fitting RPE is not suitable where facial hair prevents a seal. Loose-fitting PAPR may be required.
- HSE: RPE fit testing guidance
Questions Before Buying
- What is the substance? Dust, fume, fibre, gas, vapour or biological hazard?
- What concentration is present? APF cannot be selected properly without exposure information.
- What filter is needed? Particle, gas, vapour or combination filter?
- Is oxygen adequate? Filtering RPE cannot be used in oxygen-deficient atmospheres.
- Can the wearer achieve a seal? Facial hair, face shape and other PPE can affect tight-fitting RPE.
- How long is the task? Comfort, breathing resistance and filter life matter during longer work.
7. Fit & Maintenance
Fit, Use and Maintenance
RPE only protects when it is fitted correctly, worn for the full hazardous task, checked before use and maintained properly. Even the correct mask and filter can fail if the face seal leaks, the wrong filter is fitted or the wearer removes it during exposure.
Donning Tight-Fitting RPE
- Cup the facepiece in the hand and position it over the nose and chin.
- Pull the headbands over the head so the upper band sits above the ears and the lower band sits at the back of the neck.
- Adjust evenly so the facepiece sits securely without distortion.
- Perform a user seal check before entering the hazardous area.
- Do not omit the seal check because an unsealed mask provides unreliable protection.
User Seal Checks
- Positive pressure check: cover the exhalation valve and exhale gently to check for leaks.
- Negative pressure check: cover the inhalation valve or filters and inhale gently to check the seal.
- Do every time: a seal check should be completed before each entry into the hazardous area.
Gas Filters
- Replace gas filters at the manufacturer’s stated use time or when chemical odour is detected, whichever comes first.
- Many gas filters have a limited life after opening even if they are not used continuously.
- Store unused filters sealed in their original packaging.
- Record filter opening dates where reusable RPE is issued.
Powered Respirators
- Check battery charge before each use.
- Verify airflow rate meets the manufacturer’s specification.
- Do not use if the fan, alarm, battery or airflow indicator is not working correctly.
- Keep hoods, hoses, seals and filters clean and undamaged.
8. Inspection
Inspection and Replacement
RPE should be inspected before use and replaced when damaged, contaminated, expired, deformed or unable to seal. Reusable RPE should also be cleaned, stored and maintained in line with manufacturer instructions.
| Inspection Point |
What to Check |
Action |
| Facepiece |
Cracks, holes, distortion or damage that may break the seal. |
Replace if damaged or distorted. |
| Valves |
Inhalation and exhalation valves are clean, flexible and undamaged. |
Replace valve or facepiece if sealing is affected. |
| Headbands and Straps |
Elasticity, secure attachment and adjustment. |
Replace if loose, stretched, split or insecure. |
| Filter Connections |
Threads, seals, fittings and correct filter seating. |
Do not use if filters cannot seat securely. |
| Gas Filters |
Expiry date, opening date and signs of breakthrough. |
Replace if expired, opened beyond service guidance or odour is detected. |
| PAPR Unit |
Battery, fan, airflow rate, hose, hood and filter status. |
Do not use until airflow and battery function are confirmed. |
| Correct Filter |
Filter type matches the specific hazard for the task. |
Change filter before work starts if incorrect. |
| User Seal Check |
Mask seals before entering hazardous area. |
Do not enter if a seal cannot be achieved. |
Replacement Triggers
- Any crack or hole in the facepiece: replace because the face seal is compromised.
- Damaged valve: replace the valve or facepiece immediately.
- Expired or exhausted gas filter: replace before use.
- Chemical odour through the filter: replace immediately because breakthrough may have occurred.
- PAPR airflow failure: replace battery, filter or component and retest before use.
- Disposable FFP mask deformed or worn beyond intended use: discard because a reliable seal may not be achieved.
9. Common Mistakes
Common RPE Mistakes
| Common Mistake |
Why It Matters / Correct Practice |
| Using a surgical or medical mask as RPE |
Medical masks are not suitable occupational RPE for airborne hazards. Use UKCA or CE-marked RPE to the correct EN standard. |
| Using FFP2 or FFP3 in oxygen-deficient atmospheres |
Filtering RPE needs breathable oxygen. Use suitable breathing apparatus for oxygen-deficient or unknown atmospheres. |
| Not completing a COSHH assessment |
Without substance and concentration information, the required APF cannot be selected correctly. |
| Not fit testing tight-fitting RPE |
A mask that does not seal to the wearer’s face can provide little meaningful protection. |
| Bearded workers using tight-fitting RPE |
Facial hair can prevent sealing. Loose-fitting powered RPE may be required. |
| Using the wrong filter |
A filter must match the substance. Organic vapour, acid gas and particle hazards require different filters. |
| Using gas filters beyond service life |
Gas filter saturation can be invisible. Replace according to manufacturer guidance and breakthrough warning signs. |
| Removing RPE inside the hazardous area |
Even short removal can cause exposure. RPE should remain on for the full hazardous task. |
10. Resources
Training and Further Resources
Workers using RPE should be trained on why it is needed, how it protects them, its limitations, how to fit it, how to complete a user seal check, how to recognise filter breakthrough and when to replace or report equipment.
Always check official guidance directly before making compliance decisions.
Internal Resources to Add
- COSHH assessment records.
- RPE selection records and APF calculations.
- Fit testing certificates and retest dates.
- RPE issue and maintenance records.
- Filter change schedules and opening-date records.
- LEV inspection records where respiratory hazards are controlled by extraction.
Document Review Log
Use this space internally to record future content reviews, compliance checks or product updates.
| Version |
Date |
Reviewed By |
Changes Made |
| 1.0 |
May 2026 |
Jaybee Supplies |
Initial Knowledge Centre page created. |
|
|
|
|
|
|
|
|